I. Introduction:
Program-controlled Filter press waste water treatment adopts PLC control which can operate all the control for filter press (e.g. compressing filter press, combining and starting liquid collection plate, relaxing filter plate and opening filter plate). And there is telecontrol connector to realize automatic telecontrol.
II. Main feature:
1. Automatic plate-pulling, controlled by electrical equipment or micro computer.
2. Hydraulic installation as driving devices for compression enlightening filter plates, pulling filter plates, The adoption of pressure meter for automatic operation of automatic regulating pressure, compression,going backward,pulling plate and so on.Filter press waste water treatment
3. Easy to run, safe and labor-saving. Push-buttons in the controlling board can make continuous operation of the filter plates. And a variety of safety installations are equipped with this model to ensure operators' fety and good performance of the filter. Filter press waste water treatment
4. Other special filter press automatic functions also can be added such as filter cloth washing system, filtrate collecting system, filter cloth shaking system, drip tray system etc. Filter press waste water treatment
III. Filter press waste water treatment has such features as follows:
Automatic Pressing and opening
Automatic feeding and filtrating
Automatic squeezing
Automatic cake washing
Automatic air blowing
Automatic open
Automatic plate shifting and cake discharging.
Automatic cloth washing--- The washing cycles can be set according to requirements(can be regulated on site)
Automatic drip tray close when cloth washing and filtrating,automatic open when cake discharging.
This type of filter press has one compact layout,It can be equiped with Belt conveyor on the bottom.
IV. Part Filter press waste water treatment Technical Parameter
Model | Filtering area (m×m) | Inner dimension of frames (mm) | cake thickness (mm) | Volume of filter chambers (L) | numbers of filter plates (PCS) | motor power (kw) | filtering press (Mpa) | machine weight (Kg) | External dimension (L×W×H) (mm) | ground dimension (mm) | ||||
L | B | D | H | C | ||||||||||
XAZ1500-30UB | 200 | 1500 × 1500 | 30 | 3025 | 49 | 5.5 | 0.5 | 11385 | 5905×1990 ×1830 | 4455 | 800 | 1990 | 1080 | 4151 |
250 | 3739 | 61 | 12165 | 6805×1990 ×1830 | 5355 | |||||||||
300 | 4413 | 74 | 13010 | 7780×1990 ×1830 | 6330 | |||||||||
350 | 5210 | 86 | 13790 | 8680×1990 ×1830 | 7230 | |||||||||
400 | 6007 | 99 | 14635 | 9655×1990 ×1830 | 8205 | |||||||||
450 | 6743 | 111 | 15415 | 10555×1990 ×1830 | 9105 | |||||||||
500 | 7478 | 123 | 16195 | 11455×1990 ×1830 | 10005 |